How do I read my YORK HVAC model number?

How do I read my YORK HVAC model number?

  1. 1st digits X is the plant. X was made in Mexican.
  2. 2nd digits B are the month. B is in February.
  3. 3rd digits F are the year.
  4. 4th digits M are the TYPES OF ITEM.
  5. The last 6 numbers.
  6. 1st digits W are Manufacturing Plant.
  7. 2nd and 4th digits 0 and 4 (number) is the year of manufacture.
  8. 3rd digits E are the month.

How many sq ft can a 5 ton AC cool?

Air Conditioning Square Footage Range by Climate Zone

ZONE 1 ZONE 3
3 Tons 1501 – 1800 sf 1601 – 1900 sf
3.5 Tons 1801 – 2100 sf 1901 – 2200 sf
4 Tons 2101 – 2400 sf 2201 – 2600 sf
5 Tons 2401 – 3000 sf 2601 – 3200 sf

How many tons is a York air conditioner?

Here’s a rundown of the range you will encounter: 18 = 1.5 tons, 24 = 2 tons, 30 – 2.5 tons, 36 = 3 tons, 42 = 3.5 tons, 48 = 4 tons, and 60 = 5 tons. And this is another one that is 2 tons. If you are unsure whether you have found the right two numbers, you can double-check it by looking for the “RLA” rating on the data plate.

How to calculate York tonnage by model number?

Take the 4th,5th & 6th digits in the m/n and divide by 12 (12,000 btu/ton). For example: D2CG180N24046ECB would be a 15 ton unit. Take the 4th,5th & 6th digits in the m/n and divide by 12 (12,000 btu/ton). For example: D2CG180N24046ECB would be a 15 ton unit.

What are the model numbers for a York Furnace?

For York, you should look for first two numbers in the model number. They are divisible by 6 or 12, which represent the nominal BTU of the system in thousands. A ton of air conditioning equals 12,000 BTU, and 48 divided by 12 equals 4, so the data plate below indicates the system is 4 tons.

What’s the difference between carrier 48tc16 and York zx04?

However, they usually don’t include the precise tonnage. My thought; because of the 2.5, 7.5 and 12.5 ton units which if expressed with whole numbers would cause confusion. Most all manufacturers when referencing tonnage round up. Carrier: 48TC16 is actual their 15 ton unit. York: ZX04 – is a 3 ton unit.

Take the 4th,5th & 6th digits in the m/n and divide by 12 (12,000 btu/ton). For example: D2CG180N24046ECB would be a 15 ton unit. Take the 4th,5th & 6th digits in the m/n and divide by 12 (12,000 btu/ton). For example: D2CG180N24046ECB would be a 15 ton unit.

Here’s a rundown of the range you will encounter: 18 = 1.5 tons, 24 = 2 tons, 30 – 2.5 tons, 36 = 3 tons, 42 = 3.5 tons, 48 = 4 tons, and 60 = 5 tons. And this is another one that is 2 tons. If you are unsure whether you have found the right two numbers, you can double-check it by looking for the “RLA” rating on the data plate.

For York, you should look for first two numbers in the model number. They are divisible by 6 or 12, which represent the nominal BTU of the system in thousands. A ton of air conditioning equals 12,000 BTU, and 48 divided by 12 equals 4, so the data plate below indicates the system is 4 tons.

However, they usually don’t include the precise tonnage. My thought; because of the 2.5, 7.5 and 12.5 ton units which if expressed with whole numbers would cause confusion. Most all manufacturers when referencing tonnage round up. Carrier: 48TC16 is actual their 15 ton unit. York: ZX04 – is a 3 ton unit.